Select Page

 

Voyager DX and FC Plus SAN Cluster

Get scalability, flexibilty and fault tolerance with Voyager DX and Voyager FC Plus Series of SAN Appliances.

StoneFly’s Voyager DX and Voyager FC Plus Series of SAN Appliances are the fourth generation of the StoneFly Voyager series of high-availability cluster appliances. They offer enhanced performance, redundancy, scalability, and availability. Voyager’s scalable architecture brings the flexibility to start small, and scale up to 14.4 PetaBytes of tiered (SAS and SSD) storage.

 

 

 

 

 

 


 



captcha
*All fields with an asterisk are required.

Technical Specifications

StoneFly StoneFusion 8.0 Base SAN Management 64-Bit Operating System on Each Cluster Node

  • Logical Volume Creation and Patented Advanced Storage Virtualization Services
  • 200 iSCSI Volumes Supported with 1022 Concurrent Host iSCSI Sessions
  • iSCSI Port Teaming, Failover and Load-Balancing
  • Volume-Level Access Control and Dynamic Volume Management
  • Support for iSCSI, SNMP Traps, UPS, Nagios, RAID Monitoring, Call Home
  • System-Wide Graphical Performance and Utilization Reporting
  • Advanced Report Management
  • Automated Online Volume / Storage Expansion

StoneFly StoneFusion 8.0 Advanced Features Package on Each Cluster Node

  • StoneFly Active / Active Clustering Services with Host and SAN Load Balancing, Seamless Failover and Failback Operations
  • StoneFly Snapshot Services with 2520 Delta-Based Snapshots per Subsystem
  • Mountable Read-Write Snapshot Volumes
  • Snapshot Schedule Utility, Command Line Interface Utility
  • StoneFly Real-Time Synchronous Mirroring of iSCSI Volumes and Nodes (Campus Mirroring)
  • Multi-Site/Multi-Appliance Replication and Unified Central Management System
  • Thin Provisioning with Space Reclamation
  • Tiered Storage Architecture with Hardware and Software Support

Available Software Upgrade Options

  • Asynchronous Replication (One-to-Many & Many-to-One)
  • Optimized Block Level Parallel Data Deduplication with High-Performance Index Engine
  • Hardware-Enabled Block Level AES 256 Volume Encryption
  • NAS with Support for CIFS/SMB and NFS Protocols
  • Fibre Channel SAN Target (License Bundled with Choice of 4Gb/8Gb/16Gb HBAs)
  • VSS Support

Voyager DX and Voyager FC Plus Series Hardware Features

StoneFly Dual 1U Storage Concentrator Cluster

  • Hot-Swappable Cluster Nodes with Failover and Failback
  • Dual Hexa-Core Storage Virtualization Engines per Cluster Node
  • 32GB or 64GB Data Packet and Command Queuing Cache for SSPP® per Cluster Node
  • Voyager DX: 6Gb or 12Gb SAS Ports on Each Cluster Node for Connection to Expansion Array(s)
  • Voyager FC Plus: 8Gb or 16Gb FC Ports on Each Cluster Node for Connection to Expansion Array(s) or FC Switch(es)
  • Scale Capacity to 1440 Drives with StoneFly Expansion Arrays/Units
    • Voyager FC Plus can scale even higher when using Fibre Channel switches between the Cluster Nodes and the Expansion Arrays
  • Supports 1Gb Copper, 10Gb RJ-45/CX4 Copper, SFP+, SR/LR Optical
  • One Gigabit Management Port per Cluster Node
  • Redundant 80-PLUS® Certified Hot-Swappable Power Supplies

StoneFly Expansion Array

  • Dual Active-Active Hot-Swappable Storage Controllers with Transparent Failover/Failback
  • 6 to 60 Hot-Swappable RAID Certified Drives per Chassis
  • Choice of Nearline SAS, Enterprise SAS, SSD or Tiered
  • RAID Levels 0, 1, 0+1, 3, 5, 6, 10, 30, 50, 60, Global Spares
  • ECC-Protected RAID Cache with Battery Backup on Each Controller for Up to 72-Hour Cache Data Protection
  • Choice of 6Gb/12Gb SAS Host Connectivity to Dual USO-HA Cluster Nodes
  • Choice of 8Gb/16Gb FC Host Connectivity to Dual USO-FC Cluster Nodes
  • Dual Out-of-Band Ethernet Interfaces for Remote Status Monitoring & Configuration
  • Redundant 80-PLUS® Certified High-Efficiency Hot-Swappable Power Supply Modules
  • Scale Capacity with Additional Expansion Units

StoneFly Expansion Unit

  • Redundant JBOD Expander Controllers for Dual RAID Controller Configurations
  • 6 to 60 Hot-Swappable RAID Certified Drives per Chassis
  • Choice of Nearline SAS, Enterprise SAS or Tiered
  • In-Band Enclosure Management Service to Monitor/Control All Enclosure Elements
  • Redundant 80-PLUS® Certified High-Efficiency Hot-Swappable Power Supply Modules

Virtual Storage for Virtualized Environments

  • VMware certified
  • Citrix Xen certified
  • Microsoft Hyper-V
  • KVM

Ease of Use

  • Web-based intuitive graphical user interface
  • Simple, on-demand, no downtime volume or storage expansion

Pin It on Pinterest